Dew point13.2°C
Humidity at the surface100%

Condensation is forming. The surface is 2.2°C below the dew point, so water will collect and mould is very likely.

What would fix it?

  • Lower humidity to 46% to keep this surface 3°C above the dew point: better extraction, drying clothes outside, lids on pans.
  • Or warm the surface: insulation of cold corners and reveals, and steady heating.

Estimates using the Magnus formula. A cheap digital hygrometer gives room temperature and humidity; an infrared thermometer gives surface temperature. For a full diagnosis, see how we inspect.

The science in one chart

WHEN DOES A WALL GET WET? (ROOM AT 20°C)0°C5°C10°C15°C20°C40%50%60%70%80%90%Relative humidity in the roomCold corner at 10°C65% RH → 13.2°C

Dew point: the blue line is the temperature at which water condenses. Any surface below the line gets wet.

  1. 1
    At 20°C and 65% humidity, any surface colder than about 13°C collects condensation.
  2. 2
    A poorly insulated corner at 10°C (red line) gets wet from about 55% humidity upwards.
  3. 3
    So there are two ways to stop it: lower the humidity (ventilation) or warm the surface (insulation and heating). Try our dew point calculator.

How to use your result

Find the cause. Fix it once.